21 research outputs found
3D Fabrication and Characterisation of Electrically Receptive PCL-Graphene Scaffolds for Bioengineered In Vitro Tissue Models
Polycaprolactone (PCL) is a well-established biomaterial, offering extensive mechanical attributes along with low cost, biocompatibility, and biodegradability; however, it lacks hydrophilicity, bioactivity, and electrical conductivity. Advances in 3D fabrication technologies allow for these sought-after attributes to be incorporated into the scaffolds during fabrication. In this study, solvent-free Fused Deposition Modelling was employed to fabricate 3D scaffolds from PCL with increasing amounts of graphene (G), in the concentrations of 0.75, 1.5, 3, and 6% (w/w). The PCL+G scaffolds created were characterised physico-chemically, electrically, and biologically. Raman spectroscopy demonstrated that the scaffold outer surface contained both PCL and G, with the G component relatively uniformly distributed. Water contact angle measurement demonstrated that as the amount of G in the scaffold increases (0.75–6% w/w), hydrophobicity decreases; mean contact angle for pure PCL was recorded as 107.22 ± 9.39°, and that with 6% G (PCL+6G) as 77.56 ± 6.75°. Electrochemical Impedance Spectroscopy demonstrated a marked increase in electroactivity potential with increasing G concentration. Cell viability results indicated that even the smallest addition of G (0.75%) resulted in a significant improvement in electroactivity potential and bioactivity compared with that for pure PCL, with 1.5 and 3% exhibiting the highest statistically significant increases in cell proliferation
A Low Latency Electrocardiographic QRS Activity Recovery Technique for Use on the Upper Left Arm
Empirical mode decomposition is used as a low latency method of recovering the cardiac ventricular activity QRS biopotential signals recorded from the upper arm. The recovery technique is tested and compared with the industry accepted technique of signal averaging using a database of “normal” rhythm traces from bipolar ECG leads along the left arm, recorded from patient volunteers at a cardiology day procedure clinic. The same partial recomposition technique is applied to recordings taken using an innovative dry electrode technology supplied by Plessey Semiconductors. In each case, signal to noise ratio (SNR) is used as a metric for comparison
Prospective Assessment of Linox Implantable Cardioverter Defibrillator Leads for Structural or Electrical Abnormalities
<p></p><p><b>Article full text</b></p>
<p><br></p>
<p>The full text of this article can
be found here<b>. </b><a href="https://link.springer.com/article/10.1007/s12325-018-0691-3">https://link.springer.com/article/10.1007/s12325-018-0691-3</a></p><p></p><p></p><p>
</p><p><br></p>
<p><b>Provide enhanced content for this
article</b></p>
<p><br></p>
<p>If you are an author of this
publication and would like to provide additional enhanced content for your
article then please contact <a href="http://www.medengine.com/Redeem/âmailto:[email protected]â"><b>[email protected]</b></a>.</p>
<p><br></p>
<p>The journal offers a range of
additional features designed to increase visibility and readership. All
features will be thoroughly peer reviewed to ensure the content is of the
highest scientific standard and all features are marked as ‘peer reviewed’ to
ensure readers are aware that the content has been reviewed to the same level
as the articles they are being presented alongside. Moreover, all sponsorship
and disclosure information is included to provide complete transparency and
adherence to good publication practices. This ensures that however the content
is reached the reader has a full understanding of its origin. No fees are
charged for hosting additional open access content.</p>
<p><br></p>
<p>Other enhanced features include,
but are not limited to:</p>
<p><br></p>
<p>• Slide decks</p>
<p>• Videos and animations</p>
<p>• Audio abstracts</p>
<p>• Audio slides</p><br><p></p